ORIGINAL PAPER
Reliability and concurrent validity of the iHandy level mobile application to measure thoracolumbar range of motion in low back pain patients
More details
Hide details
1
Riphah College of Rehabilitation and Allied Health Sciences, Riphah International University, Lahore, Pakistan
2
Ayesha Bakht Institute of Medical Sciences, Lahore, Pakistan
3
Resident at Riphah Rehabilitation Centre, Lahore, Pakistan
4
University of Management and Technology, Lahore, Pakistan
Submission date: 2023-07-10
Acceptance date: 2023-10-25
Publication date: 2024-12-06
Corresponding author
Nimra Ijaz
Royal Hospital for Neurodisability, West Hill, London, SW15 3SW, London, UK
Physiother Quart. 2024;32(4):68-73
KEYWORDS
TOPICS
ABSTRACT
Introduction:
The use of smartphone technology and software (apps), in addition to an inclinometer and goniometer, has expanded the clinician’s assessment possibilities. However, the legitimacy and trustworthiness of these cell phones and applications are still questioned. This study aimed to determine the reliability and concurrent validity of the iHandy level mobile application to measure the thoracolumbar range of motion in people with low back pain.
Methods:
This descriptive study included 40 participants, of which 20 were symptomatic, and 20 were asymptomatic for non-specific chronic pain in the lower back. Measurements were taken for extension, flexion, and left and right-side bending range of motion (ROM). Two investigators were involved. One measured ROM values with a Samsung iHandy level and inclinometer, and the second investigator registered the data. Two values were taken and the mean was used for further analysis. Measurements were taken at baseline and one-week follow-up.
Results:
In asymptomatic participants, the mobile application had ICC values of 0.81, 0.70, 0.79, and 0.85, while in symptomatic, regarding intra-rater reliability, these were 0.80, 0.78, 0.81Regarding the concurrent validity of mobile apps in asymptomatic patients, ICC values were 0.94, 0.93, 0.84, and 0.89, while in symptomatic patients, the ICC values were found to be 0.92, 0.89, 0.83, and 0.85 for flexion, extension, RLF, and LLF, respectively. These showed an excellent correlation between the inclinometer and mobile app regarding intra-rater reliability and concurrent validity.
Conclusions:
iHandy level smartphone applications might be considered reliable and valid for assessing thoracolumbar motion ranges in individuals with chronic pain in the lower back.
REFERENCES (24)
1.
Hartvigsen J, Hancock MJ, Kongsted A, Louw Q, Ferreira ML, Genevay S, Hoy D, Karppinen J, Pransky G, Sieper J, Smeets RJ, Underwood M; Lancet Low Back Pain Series Working Group. What low back pain is and why we need to pay attention. Lancet. 2018;391(10137):2356–67; doi: 10.1016/S0140-6736(18)30480-X.
2.
Russo M, Deckers K, Eldabe S, Kiesel K, Gilligan C, Vieceli J, Crosby P. Muscle control and non-specific chronic low back pain. Neuromodulation. 2018;21(1):1–9; doi: 10.1111/ner.12738.
3.
Chiarotto A, Koes BW. Non-specific low back pain. N Engl J Med. 2022;386(18):1732–40; doi: 10.1056/NEJMcp2032396.
4.
Oliveira CB, Maher CG, Pinto RZ, Traeger AC, Lin C-WC, Chenot J-F, van Tulder M, Koes BW. Clinical practice guidelines for the management of non-specific low back pain in primary care: an updated overview. Eur Spine J. 2018;27(11):2791–803; doi: 10.1007/s00586-018-5673-2.
5.
Alsufiany MB, Lohman EB, Daher NS, Gang GR, Shallan AI, Jaber HM. Non-specific chronic low back pain and physical activity: a comparison of postural control and hip muscle isometric strength: a cross-sectional study. Medicine. 2020;99(5):e18544; doi: 10.1097/MD.0000000000018544.
6.
Jayavel A, Misra P, Sivakumar V. Reliability and validity of I handy android application on measurement of lumbar spine movement in patients with low back pain. Int J Clin Skills. 2017;11(3):84–8.
7.
Keogh JW, Cox A, Anderson S, Liew B, Olsen A, Schram B, Furness J. Reliability and validity of clinically accessible smartphone applications to measure joint range of motion: a systematic review. PLOS ONE. 2019;14(5):e0215806; doi: 10.1371/journal.pone.0215806.
8.
Pourahmadi MR, Taghipour M, Jannati E, Mohseni-Bandpei MA, Takamjani IE, Rajabzadeh F. Reliability and validity of an iPhone® application for the measurement of lumbar spine flexion and extension range of motion. PeerJ. 2016;4:e2355; doi: 10.7717/peerj.2355.
9.
Kolber MJ, Pizzini M, Robinson A, Yanez D, Hanney WJ. The reliability and concurrent validity of measurements used to quantify lumbar spine mobility: an analysis of an iphone® application and gravity based inclinometry. Int J Sports Phys Ther. 2013;8(2):129.
10.
Furness J, Schram B, Cox AJ, Anderson SL, Keogh J. Reliability and concurrent validity of the iPhone® Compass application to measure thoracic rotation range of motion (ROM) in healthy participants. PeerJ. 2018;6:e4431; doi: 10.7717/peerj.4431.
11.
de Brito Macedo L, Borges DT, Melo SA, da Costa KSA, de Oliveira Sousa C, Brasileiro JS. Reliability and concurrent validity of a mobile application to measure thoracolumbar range of motion in low back pain patients. J Back Musculoskelet Rehabil. 2020;33(1):145–51.
12.
Boudreau N, Brochu F-O, Dubreuil L-M, Laurendeau T, Leblanc O, De Vette E, Tousignant-Laflamme Y. Reliability and criterion validity of the “Gyroscope” application of the iPod™ for measuring lumbar range of motion. J Back Musculoskelet Rehabil. 2020;33(4):685–92; doi: 10.3233/BMR-181184.
13.
Ceballos-Laita L, Mingo-Gómez T, Mar Latorre-Balsa M, Jiménez-del-Barrio S. Reliability of two smartphone applications to measure the hip range of motion in asymptomatic patients. Arch Phys Glob Res. 2019;23(1):21–7; doi: 10.15442/apgr.23.1.3.
14.
Park H-Y, Hwang U-J, Kwon O-Y. The reliability and validity of the digital goniometer and smart phone to determine trunk active range of motion in stroke patients. Phys Ther Korea. 2022;29(3):225–34; doi: 10.12674/ptk.2022.29.3.225.
15.
Nuhmani S, Khan MH, Kachanathu SJ, Bari MA, Abualait TS, Muaidi QI. Reliability and validity of smartphone applications to measure the spinal range of motion: a systematic review. Expert Rev Med Device. 2021;18(9):893–901; doi: 10.1080/17434440.2021.1962290.
16.
Cánovas-Ambit G, García-Vidal JA, Martín-San Agustín R, Dalla-Vecchia AA, Sánchez-Barbadora M, Medina-Mirapeix F. Validity and reliability of Veloflex to measure active cervical range of motion in asymptomatic and symptomatic subjects. PeerJ. 2021;9:e11228; doi: 10.7717/peerj.11228.
17.
Monreal C, Luinstra L, Larkins L, May J. Validity and intrarater reliability using a smartphone clinometer application to measure active cervical range of motion including rotation measurements in supine. J Sport Rehabil. 2020;30(4):680–4; doi: 10.1123/jsr.2019-0422.
18.
Caña-Pino A, Espejo-Antúnez L, Adsuar JC, Apolo-Arenas MD. Test-retest reliability of an iphone® inclinometer application to assess the lumbar joint repositioning error in non-specific chronic low back pain. Int J Environ Res Public Health. 2021;18(5):2489; doi: 10.3390/ijerph18052489.
19.
Wellmon RH, Gulick DT, Paterson ML, Gulick CN. Validity and reliability of 2 goniometric mobile apps: device, application, and examiner factors. J Sport Rehabil. 2016;25(4):371–9; doi: 10.1123/jsr.2015-0041.
20.
Elgueta-Cancino E, Schabrun S, Danneels L, Van Den Hoorn W, Hodges P. Validation of a clinical test of thoracolumbar dissociation in chronic low back pain. J Orthop Sports Phys Ther. 2015;45(9):703–12; doi: 10.2519/jospt.2015.5590.
21.
Sánchez-Zuriaga D, López-Pascual J, Garrido-Jaén D, García-Mas MA. A comparison of lumbopelvic motion patterns and erector spinae behavior between asymptomatic subjects and patients with recurrent low back pain during pain-free periods. J Manipulative Physiol Ther. 2015;38(2):130–7; doi: 10.1016/j.jmpt.2014.11.002.
22.
Zawadka M, Skublewska-Paszkowska M, Gawda P, Lukasik E, Smolka J, Jablonski M. What factors can affect lumbopelvic flexion-extension motion in the sagittal plane? A literature review. Hum Mov Sci. 2018;58:205–18.
23.
Yezzi-Woodley K, Calder J, Olver PJ, Cody P, Huffstutler T, Terwilliger A, Melton JA, Tappen M, Coil R, Tostevin G. The virtual goniometer: demonstrating a new method for measuring angles on archaeological materials using fragmentary bone. Archaeol Anthropol Sci. 2021;13(7):106; doi: 10.1007/s12520-021-01335-y.
24.
Aspinall S, Sparks T, King A, Price M, Godsiff S. A mobile APP to replace the Goniometer? A pilot study focusing on the measurement of knee range of movement. J Sports Sci. 2019;7(3):71–80.